To Configure Startup Fuel Matt May 06, 2018 15:48 Follow The Power Commander V allows you to add or take out fuel upon engine startup. 1 Select Power Commander Tools Configure Startup Fuel. 2 To configure the startup fuel using Run Time, click here. 2a Select the Enabled box. 2b Using the Mode drop-down list, select Run Time. 2c Enter the desired startup time in the Run Time field. 2d Enter the desired amount of fuel adjustment in the Add Fuel field. 2e Click OK to accept the changes. Or Click Cancel to close the window without changes. 3 To configure the startup fuel using Engine Temperature, click here. 3a Select the Enabled box. 3b Using the Mode drop-down list, select Engine Temperature. 3c Using the drop-down list, select the number of columns. 3d Enter a temperature and a corresponding fuel adjustment in each column. Note: You must configure Engine Temperature before using the temperature option in Startup Fuel. 3e Click OK to accept the changes. Or Click Cancel to close the window without changes. Related articles To Calibrate the Throttle Position in PCV Software To Configure the Pressure Table Axis To Calibrate the Speed Installation instruction for MAP sensor for PTI units Table Manager Comments 0 comments Please sign in to leave a comment.